| Peso | 3000 g |
|---|---|
| Dimensões | 365 × 225 × 190 mm |
KIT CONTÉM:
1 – Osciloscópio digital 25MHz 2530B B&K Precision;
1 – Cabo de energia;
1 – Ponta de prova x10;
1 – Manual;
1 – CD.
ALTURA: 160MM;
LARGURA: 305MM;
PROFUNDIDADE: 133MM;
PESO: 2,3KG.
Specifications:
Inputs
Input Coupling AC, DC, GND
Input Impedance 1 MΩ ± 2% || 16 pf ± 3 pf
Maximum input voltage 400 V (DC+AC PK-PK, 1 MΩ input
impedance, X10), CAT I
5 Vrms; +/-10 V Peak for 1 s pulse, 50
% duty cycle (50 Ω BNC)
Ch to Ch Isolation >100:1 at 10 MHz
Probe attenuator: 1X, 10X
Probe attenuation selectable factors: 1X, 10X, 100X, 1000X
Vertical System:
Vertical Sensitivity: 2 mV/div – 10 V/div (1-2-5 order)
Channel voltage offset range: 2 mV–100 mV: ±2 V 102 mV – 10 V: ±40 V
Vertical Resolution: 8 bit
Channels: 2
Analog Bandwidth: 25 MHz
Single-shot Bandwidth: 25 MHz
Lower frequency limit (AC – coupled): ≤10 Hz (at input BNC)
DC Gain Accuracy: < ± 3.0%: 10 mV/div to 10 V/div in fixed gain ranges < ± 4.0%: 2 mV/div , 5 mV/div and variable gain ranges
DC Measurement Accuracy: All Gain settings ≤100mV/div: ± [3%*(|reading|+|offset|)+1% *|offset| +0.2 div+2 mV]
DC Measurement Accuracy: All Gain settings >100mV/div: ± [3%*(|reading|+|offset|)+ 1%* offset| +0.2 div+100 mV]
Rise time: <14 ns
Overshoot, Typical (using 500 ps pulse): <10% with probe or BNC input w/ 50 Ohm feed thru
Math operation: +, -, *, /, FFT
FFT: Window mode: Hanning, Hamming, Blackman, Rectangular
Sampling points: 1024
Horizontal System:
Real Time Sampling Rate:
Single Channel: 500 MSa/s
Dual Channel: 250 MSa/s (when timebase is faster than 250 nS/div)
Highest Equivalent Sampling Rate: 10 GSa/s.
Measure Display Modes: MAIN, WINDOW, WINDOW ZOOM, ROLL, X-Y
Timebase Accuracy: ±100ppm measured over 1ms interval
Horizontal Scan Range: 25 nS/DIV – 50 S/DIV
Scan Mode: 100 mS/DIV – 50 S/DIV (1-2.5-5 sequence)
Maximum Memory Length (interleaved): 32,000 points*
(16000 points for dual channel operation)
*The number of data points depends on the timebase setting and whether or not the oscilloscope is in single or dual channel mode. More details on how many datapoints can be saved to a CSV file can be found in the storage chapter of this manual. The number of datapoints that can be captured via USB device interface using the EasyScope software is specified in the EasyScope manual.
Trigger System:
Trigger Types: Edge, Pulse Width, Video, Slope, Alternative
Trigger Source: CH1,CH2, ,EXT,EXT/5, AC Line
Trigger Modes: Auto, Normal, Single
Trigger Coupling: AC, DC, LF reject, HF reject
Trigger Level Range: CH1,CH2: ± 6 divisions from center of screen
EXT: ±1.2 V
EXT/5: ±6 V
Trigger Level Accuracy (typical) applicable for the signal of rising and falling time ≥20ns:
Internal: ±(0.2 div×V/div) ( within ± 4 divisions from center of screen)
EXT: ±(6% of setting + 40 mV)
EXT/5: ±(6% of setting + 200 mV)
Trigger Sensitivity:
For fixed gain ranges
1 Divisions: DC-10 MHz
1.5 Divisions: 10 MHz – max. bandwidth
EXT: 200 mVpp DC-10 MHz,
300 mVpp 10 MHz – max. bandwidth
EXT/5: 1 Vpp DC-10 MHz,
1.5 Vpp 10 MHz – max. bandwidth
Pulse Width Trigger:
Trigger Modes: (>, <, =) positive Pulse
Width, (>, <, =) Negative Pulse Width
Pulse width range: 20 ns – 10 s
Video Trigger:
Support signal formats: PAL/SECAM, NTSC
Trigger condition: odd field, even field, all lines, line Num
Slope Trigger:
(>, <, =) Positive slope, (>, <, =) Negative slope
Time: 20 ns-10 s
Alternative Trigger:
CH1 trigger type: Edge, Pulse, Video, Slope
CH2 trigger type: Edge, Pulse, Video, Slope
Display System:
Display Mode: Color TFT 5.7 in(145 mm)
diagonal Liquid
Crystal Display
Resolution 320 horizontal by 240 vertical pixels
Display Color: 64K color
Display Contrast (Typical state): 150:1
Backlight Intensity (Typical state): 300 cd/m2
Wave display range: 8 x 12 div
Wave Display Mode: Dots, Vector
Persist: Off, 1 sec, 2 sec, 5 sec, Infinite
Menu Display: 2 sec, 5 sec, 10 sec, 20 sec,
Infinite
Screen-Saver: Off, 1 min, 2 min, 5 min, 10 min, 15 min, 30 min, 1 hour, 2 hour, 5 hour
Skin: Classical, Modern, Tradition, Succinct
Waveform interpolation: Sin(x)/x, Linear
Color model: Normal , Invert
Language: Simplified Chinese, Traditional Chinese, English, Arabic, French, German, Russian, Spanish, Portuguese, Japanese, Korean, Italian
X-Y Mode
X-pole Input / Y-Pole Input: Channel 1 (CH1) / Channel 2 (CH2)
Phase Error: ± 3 degrees
Hardware Frequency Counter
Reading resolution: 6 Bytes
Accuracy: ±0.01%
Range: DC Couple, 10 Hz to 25 MHz
Signal Types: Satisfying all trigger signals (except pulse width trigger and video trigger)
Environment Condition
Temperature: Operating: 50° F to 104 °F (10 °C to +40°C)
Not operating: -4 °F to 140 °F (-20 °C to+60 °C)
Cooling: Internal cooling fan
Humidity: Operating: 85% RH, 104 °F (40 °C), 24 hours
Not operating: 85% RH, 149 °F (65 °C), 24 hours
Elevation: Operating: 9,842.5 ft (3,000m)
Nonoperating: 50,085.3 ft (15,266m)
Control Panel Function
Auto Set: Auto adjusting the Vertical, Horizontal system and Trigger Position
Save/Recall: save/recall 2 referenced waveforms, 20 setups, and 10 captured waveforms to/from internal memory or to external USB flash drive.
Power Supply
Input Voltage: 100-240 VAC, CAT II, Auto selection
Frequency Range: 45Hz to 440Hz
Power: 50VA Max
Interface
USB: USB Device Port: For PC interface with EasyScope software
USB Host Port: For Flash Drives
Para mais informações, entre em contato conosco!